UCL  IRIS
Institutional Research Information Service
UCL Logo
Please report any queries concerning the funding data grouped in the sections named "Externally Awarded" or "Internally Disbursed" (shown on the profile page) to your Research Finance Administrator. Your can find your Research Finance Administrator at http://www.ucl.ac.uk/finance/research/post_award/post_award_contacts.php by entering your department
Please report any queries concerning the student data shown on the profile page to:

Email: portico-services@ucl.ac.uk

Help Desk: http://www.ucl.ac.uk/ras/portico/helpdesk
Publication Detail
Low-cost surface reconstruction for aesthetic results assessment and prediction in breast cancer surgery
  • Publication Type:
    Conference
  • Authors:
    Lacher RM, Hipwell JH, Williams NR, Keshtgar MRS, Hawkes DJ, Stoyanov D
  • Publication date:
    04/11/2015
  • Pagination:
    5871, 5874
  • Published proceedings:
    Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS
  • Volume:
    2015-November
  • ISBN-13:
    9781424492718
  • Status:
    Published
  • Print ISSN:
    1557-170X
Abstract
© 2015 IEEE.The high incidence and low mortality of breast cancer surgery has led to an increasing emphasis on the cosmetic outcome of surgical treatment. Advances in aesthetic evaluation, as well as surgical planning and outcome prediction, have been investigated by using geometrically precise 3D modelling of the breast surface prior to surgery and after the procedure. However, existing solutions are based on expensive site specific setups and remain weakly validated. In this paper, we explore the possibility of using low-cost RGBD cameras as an affordable and mobile system for breast surface reconstruction. The methodology relies on sensor calibration, uncertainty-driven point filtering, dense reconstruction and subsequent multi-view joint optimization to diffuse residual pose errors. Results from a phantom study, with ground truth obtained through commercially available scanners, indicate that the approach is promising with RMS errors in order of 2 mm. A clinical study shows the practical applicability of our method and compares favourably to high-end scanning solutions.
Publication data is maintained in RPS. Visit https://rps.ucl.ac.uk
 More search options
There are no UCL People associated with this publication
University College London - Gower Street - London - WC1E 6BT Tel:+44 (0)20 7679 2000

© UCL 1999–2011

Search by