UCL  IRIS
Institutional Research Information Service
UCL Logo
Please report any queries concerning the funding data grouped in the sections named "Externally Awarded" or "Internally Disbursed" (shown on the profile page) to your Research Finance Administrator. Your can find your Research Finance Administrator at https://www.ucl.ac.uk/finance/research/rs-contacts.php by entering your department
Please report any queries concerning the student data shown on the profile page to:

Email: portico-services@ucl.ac.uk

Help Desk: http://www.ucl.ac.uk/ras/portico/helpdesk
Publication Detail
Aerosol-Assisted CVD-Grown PdO Nanoparticle-Decorated Tungsten Oxide Nanoneedles Extremely Sensitive and Selective to Hydrogen
  • Publication Type:
    Journal article
  • Publication Sub Type:
    Article
  • Authors:
    Annanouch FE, Haddi Z, Ling M, Di Maggio F, Vallejos S, Vilic T, Zhu Y, Shujah T, Umek P, Bittencourt C, Blackman C, Llobet E
  • Publication date:
    27/04/2016
  • Pagination:
    10413, 10421
  • Journal:
    ACS Applied Materials and Interfaces
  • Volume:
    8
  • Issue:
    16
  • Status:
    Published
  • Print ISSN:
    1944-8244
Abstract
© 2016 American Chemical Society.We report for the first time the successful synthesis of palladium (Pd) nanoparticle (NP)-decorated tungsten trioxide (WO3) nanoneedles (NNs) via a two-step aerosol-assisted chemical vapor deposition approach. Morphological, structural, and elemental composition analysis revealed that a Pd(acac)2 precursor was very suitable to decorate WO3 NNs with uniform and well-dispersed PdO NPs. Gas-sensing results revealed that decoration with PdO NPs led to an ultrasensitive and selective hydrogen (H2) gas sensor (sensor response peaks at 1670 at 500 ppm of H2) with low operating temperature (150 °C). The response of decorated NNs is 755 times higher than that of bare WO3 NNs. Additionally, at a temperature near that of the ambient temperature (50 °C), the response of this sensor toward the same concentration of H2 was 23, which is higher than that of some promising sensors reported in the literature. Finally, humidity measurements showed that PdO/WO3 sensors displayed low-cross-sensitivity toward water vapor, compared to bare WO3 sensors. The addition of PdO NPs helps to minimize the effect of ambient humidity on the sensor response.
Publication data is maintained in RPS. Visit https://rps.ucl.ac.uk
 More search options
UCL Researchers
Author
Dept of Chemistry
University College London - Gower Street - London - WC1E 6BT Tel:+44 (0)20 7679 2000

© UCL 1999–2011

Search by