UCL  IRIS
Institutional Research Information Service
UCL Logo
Please report any queries concerning the funding data grouped in the sections named "Externally Awarded" or "Internally Disbursed" (shown on the profile page) to your Research Finance Administrator. Your can find your Research Finance Administrator at http://www.ucl.ac.uk/finance/research/post_award/post_award_contacts.php by entering your department
Please report any queries concerning the student data shown on the profile page to:

Email: portico-services@ucl.ac.uk

Help Desk: http://www.ucl.ac.uk/ras/portico/helpdesk
Publication Detail
Capabilities of laser ablation-ICP-TOF-MS coupling for isotopic analysis of individual uranium micrometric particles
  • Publication Type:
    Journal article
  • Publication Sub Type:
    Journal Article
  • Authors:
    Ronzani AL, Pointurier F, Rittner M, Borovinskaya O, Tanner M, Hubert A, Humbert AC, Aupiais J, Dacheux N
  • Publication date:
    01/11/2018
  • Pagination:
    1892, 1902
  • Journal:
    Journal of Analytical Atomic Spectrometry
  • Volume:
    33
  • Issue:
    11
  • Status:
    Published
  • Print ISSN:
    0267-9477
Abstract
© 2018 The Royal Society of Chemistry. Capabilities of laser ablation coupled to a time of flight ICP-MS ('icpTOF', Tofwerk) for direct isotopic analysis of U micrometric reference particles deposited on carbon disks were demonstrated. Thanks to the very high temporal resolution which allows quasi simultaneous measurement of all nuclides, the icpTOF is well-suited for the acquisition of the very short transient signals produced by laser ablation of μm-sized particles. With appropriate corrections of the background due to high peak tailing of the 238U isotope and selection of signals within the detector's linear range, excellent internal and external precisions (0.2-0.4%) for measurement of the 235U/238U ratios were obtained in the most favorable cases (same abundances for the two isotopes). These precisions are better than the values reported until now in the literature, even with laser ablation coupled with multi-collector ICP-MS (MC-ICP-MS). For particles from other reference materials with low abundances of 235U, equal or close to the one of natural U, precisions for 235U/238U ratio measurements (4-5%) were not as good as the ones reported for MC-ICP-MS, but better than the ones obtained with single collector ICP-MS. Minor isotope ratios (234U/238U and 236U/238U) were also successfully measured, although with limited precision and accuracy when the abundances of the minor isotopes are very low, in the 10-5 range. This work shows that laser ablation coupled to ICP-TOF-MS has a great potential for ultra-precise isotope ratio measurements provided that the ablated area contains enough analyte and that abundances between isotopes are of the same order of magnitude.
Publication data is maintained in RPS. Visit https://rps.ucl.ac.uk
 More search options
There are no UCL People associated with this publication
University College London - Gower Street - London - WC1E 6BT Tel:+44 (0)20 7679 2000

© UCL 1999–2011

Search by