UCL  IRIS
Institutional Research Information Service
UCL Logo
Please report any queries concerning the funding data shown on the profile page to:

http://www.ucl.ac.uk/finance/secure/research/post_award
Please report any queries concerning the student data shown on the profile page to:

Email: portico-services@ucl.ac.uk

Help Desk: http://www.ucl.ac.uk/ras/portico/helpdesk
Publication Detail
In vivo study of a model tissue-engineered small-diameter vascular bypass graft.
  • Publication Type:
    Journal article
  • Publication Sub Type:
    Journal Article
  • Authors:
    Baguneid M, de Mel A, Yildirimer L, Fuller BJ, Hamilton G, Seifalian AM
  • Publication date:
    01/2011
  • Pagination:
    14, 24
  • Journal:
    Biotechnol Appl Biochem
  • Volume:
    58
  • Issue:
    1
  • Country:
    England
  • Language:
    eng
  • Keywords:
    Coated Materials, Biocompatible, Coronary Artery Bypass, Endothelial Cells, Graft Occlusion, Vascular, Hemodynamics, Humans, Models, Biological, Myocytes, Smooth Muscle, Stress, Mechanical, Tissue Engineering
Abstract
Conventionally used vascular grafts such as polyester (Dacron) or expanded polytetrafluoroethylene perform inadequately as small-diameter vascular bypass grafts (SDBGs). SDBGs, which can maintain long-term patency and those that could potentially evolve with the somatic growth, are highly desirable in vascular surgery and thus research into tissue-engineered blood vessels (TEBVs) is of keen interest. A TEBV was developed by seeding endothelial cells onto a collagen matrix that was cross-linked and contracted by smooth muscle cells (SMCs). A polyester graft served as a scaffold. Recovery studies (12 TEBVs and seven controls) were carried out to assess in vivo endothelialization and long-term patency of TEBVs. Hemodynamic observations indicated para-anastomotic turbulences and high shear stress at anastomosis. Recovery studies demonstrated confluent endothelialization, thrombus-free surfaces, and patent TEBVs in all cases. Graft incorporation and neovascularization of the scaffold occurred in both hybrid and control grafts. However, thickened neointima formation occurred in TEBV grafts, which was most likely caused by the rigidity of polyester scaffold. Significant perigraft inflammatory changes could be observed in both TEBVs and control grafts at 1, 4, and 8 weeks. In conclusion, the TEBVs demonstrated satisfactory performance as an infra-renal-aortic graft in a porcine model. The TEBV serves as a promising model and facilitates the development of a TEBV in a clinical setting, potentially with human stem cells and with more biocompatible, biodegradable scaffolds that are mechanically more compliant with natural vessels.
Publication data is maintained in RPS. Visit https://rps.ucl.ac.uk
 More search options
UCL Authors Show More
Research Department of General Surgery
Research Department of General Surgery
Div of Surgery & Interventional Sci
Research Department of General Surgery
University College London - Gower Street - London - WC1E 6BT Tel:+44 (0)20 7679 2000

© UCL 1999–2011

Search by