UCL  IRIS
Institutional Research Information Service
UCL Logo
Please report any queries concerning the funding data shown on the profile page to:

http://www.ucl.ac.uk/finance/secure/research/post_award
Please report any queries concerning the student data shown on the profile page to:

Email: portico-services@ucl.ac.uk

Help Desk: http://www.ucl.ac.uk/ras/portico/helpdesk
Publication Detail
Ozonolysis in Flow Using Capillary Reactors
  • Publication Type:
    Journal article
  • Publication Sub Type:
    Article
  • Authors:
    Roydhouse MD, Ghaini A, Constantinou A, Cantu-Perez A, Motherwell WB, Gavriilidis A
  • Publisher:
    AMER CHEMICAL SOC
  • Publication date:
    09/2011
  • Pagination:
    989, 996
  • Journal:
    ORG PROCESS RES DEV
  • Volume:
    15
  • Issue:
    5
  • Print ISSN:
    1083-6160
  • Language:
    EN
  • Keywords:
    AIR-WATER FLOW, MICROSTRUCTURED REACTORS, GAS-LIQUID, PRESSURE-DROP, VOID FRACTION, REDUCTION, PATTERN, OZONE
  • Addresses:
    Gavriilidis, A
    UCL
    Dept Chem Engn
    London
    WC1E 7JE
    England
Abstract
Reactions of n-decene with ozone and subsequent quenching of the formed ozonides were carried out under flow conditions using the standard Vapourtec flow system equipped with a cooled flow cell. The reactions were performed continuously and in the annular flow regime within the circular cross-section channels. Typical flow rates were 0.25-1 mL min(-1) for liquid and 25-100 mL min(-1) for gas, reactor volumes were 0.07-10 mL formed of 1 mm ID PFA tubing. The reaction temperature was -10 degrees C. The flow was not always smooth, while waves in the liquid film and droplets in the gas core were observed. Liquid residence times were found to be independent of gas flow rates and increasing with decreasing liquid flow rates. Substrate residence times in the ozonolysis reactor ranged between 1 and 80s, and complete conversion could be achieved at similar to 1 s residence time. Two common reductants, triethylphosphite and triphenylphosphine, were examined as to their suitability under flow conditions. Triphenylphosphine achieved faster reduction of the intermediate ozonides, resulting in a greater than 10:1 selectivity for the aldehyde over the corresponding acid. The cooling system provided a safe and efficient control of the highly exothermic reaction system. The configuration of the system allowed the production of chemically significant amounts (1.8 g h(-1) 1.3 ozone equivalents), with minimal amounts of ozonides present at any time.
Publication data is maintained in RPS. Visit https://rps.ucl.ac.uk
 More search options
UCL Authors
Dept of Chemical Engineering
University College London - Gower Street - London - WC1E 6BT Tel:+44 (0)20 7679 2000

© UCL 1999–2011

Search by