Please report any queries concerning the funding data grouped in the sections named "Externally Awarded" or "Internally Disbursed" (shown on the profile page) to your Research Finance Administrator. Your can find your Research Finance Administrator at https://www.ucl.ac.uk/finance/research/rs-contacts.php by entering your department
Please report any queries concerning the student data shown on the profile page to:

Email: portico-services@ucl.ac.uk

Help Desk: http://www.ucl.ac.uk/ras/portico/helpdesk
Publication Detail
An integrated implantable stimulator that is fail-safe without off-chip blocking-capacitors
Abstract
We present a neural stimulator chip with an output stage (electrode driving circuit) that is fail-safe under single-fault conditions without the need for off-chip blocking-capacitors. To miniaturize the stimulator output stage two novel techniques are introduced. The first technique is a new current generator circuit reducing to a single step the translation of the digital input bits into the stimulus current, thus minimizing silicon area and power consumption compared to previous works. The current generator uses voltage-controlled resistors implemented by MOS transistors in the deep triode region. The second technique is a new stimulator output stage circuit with blocking-capacitor safety protection using a high-frequency current-switching (HFCS) technique. Unlike conventional stimulator output stage circuits for implantable functional electrical stimulation (FES) systems which require blocking-capacitors in the microfarad range, our proposed approach allows capacitance reduction to the picofarad range, thus the blocking-capacitors can be integrated on-chip. The prototype four-channel neural stimulator chip was fabricated in XFAB's 1-μm silicon-on-insulator CMOS technology and can operate from a power supply between 5-18 V. The stimulus current is generated by active charging and passive discharging. We obtained recordings of action potentials and a strength-duration curve from the sciatic nerve of a frog with the stimulator chip which demonstrate the HFCS technique. The average power consumption for a typical 1-mA 20-Hz single-channel stimulation using a book electrode, is 200 μW from a 6 V power supply. The silicon area occupation is 0.38 mm2 per channel.
Publication data is maintained in RPS. Visit https://rps.ucl.ac.uk
 More search options
UCL Researchers
Author
Dept of Med Phys & Biomedical Eng
Author
Dept of Electronic & Electrical Eng
University College London - Gower Street - London - WC1E 6BT Tel:+44 (0)20 7679 2000

© UCL 1999–2011

Search by