UCL  IRIS
Institutional Research Information Service
UCL Logo
Please report any queries concerning the funding data shown on the profile page to:

http://www.ucl.ac.uk/finance/secure/research/post_award
Please report any queries concerning the student data shown on the profile page to:

Email: portico-services@ucl.ac.uk

Help Desk: http://www.ucl.ac.uk/ras/portico/helpdesk
Publication Detail
The effects of microporosity on osteoinduction of calcium phosphate bone graft substitute biomaterials.
  • Publication Type:
    Journal article
  • Publication Sub Type:
    Journal Article
  • Authors:
    Chan O, Coathup MJ, Nesbitt A, Ho CY, Hing KA, Buckland T, Campion C, Blunn GW
  • Publication date:
    07/2012
  • Pagination:
    2788, 2794
  • Journal:
    Acta Biomater
  • Volume:
    8
  • Issue:
    7
  • Country:
    England
  • PII:
    S1742-7061(12)00133-X
  • Language:
    eng
  • Keywords:
    Animals, Biocompatible Materials, Bone Substitutes, Bone Transplantation, Calcium Phosphates, Female, Implants, Experimental, Microscopy, Electron, Scanning, Osseointegration, Osteogenesis, Porosity, Prosthesis Implantation, Sheep, Tissue Scaffolds
Abstract
The effect of increasing strut porosity on the osteoinductive ability of silicate substituted calcium phosphate (SiCaP) biomaterials was investigated in an ectopic ovine model. Implants with strut porosities of 22.5%, 32.0% and 46.0% were inserted into the parapsinalis muscle. At 8, 12 and 24 weeks histological sections were prepared. Sections were examined using backscattered scanning electron microscopy and un-decalcified histology. Bone area, implant area and bone-implant contact were quantified. At 8 weeks there was no significant difference between the groups in terms of bone area and implant area. However at 12 weeks, the amount of bone formation observed was significantly greater in SiCaP-46 (6.17 ± 1.51%) when compared with SiCaP-22.5 (1.33 ± 0.84%) p=0.035. Results also showed significantly increased amounts of bone-implant contact to the SiCaP-46 scaffold (3.30 ± 1.17%) compared with SiCaP-22.5 (0.67 ± 0.52%, p=0.043) at 8 weeks and 12 weeks; (SiCaP-46 (21.82 ± 5.59%) vs SiCaP-22.5 (3.06 ± 1.89%), p=0.012). At 24 weeks, bone formation and graft resorption had significantly increased in all groups so that the level of bone formation in the SiCaP-46 group had increased 75-fold to 30.05 ± 8.38%. Bone formation was observed in pores <10 μm. Results suggest that bone graft substitute materials with greater strut porosity are more osteoinductive.
Publication data is maintained in RPS. Visit https://rps.ucl.ac.uk
 More search options
UCL Authors
Inst of Orthopaedics & Musculosk Sci
Inst of Orthopaedics & Musculosk Sci
University College London - Gower Street - London - WC1E 6BT Tel:+44 (0)20 7679 2000

© UCL 1999–2011

Search by