Please report any queries concerning the funding data grouped in the sections named "Externally Awarded" or "Internally Disbursed" (shown on the profile page) to your Research Finance Administrator. Your can find your Research Finance Administrator at http://www.ucl.ac.uk/finance/research/post_award/post_award_contacts.php by entering your department
Please report any queries concerning the student data shown on the profile page to:

Email: portico-services@ucl.ac.uk

Help Desk: http://www.ucl.ac.uk/ras/portico/helpdesk
Publication Detail
A new algorithm for deriving pulsatile blood flow waveforms tested using stimulated dynamic angiographic data
  • Publication Type:
    Journal article
  • Publication Sub Type:
    Article
  • Authors:
    Seifalian AM, Hawkes DJ, Colchester AC, Hobbs KE
  • Publication date:
    1989
  • Pagination:
    263, 269
  • Journal:
    NEURORADIOLOGY
  • Volume:
    31
  • Issue:
    028-3940 (Print), 3
  • Print ISSN:
    0028-3940
  • Keywords:
    administration & dosage, Algorithms, Angiography, blood, Blood Flow Velocity, Computer Simulation, Contrast Media, Humans, Injections, London, methods, pathology, Pulsatile Flow, Research Support, Non-U.S.Gov't, surgery, Time Factors
  • Addresses:
    Academic Department of Surgery, Royal Free Hospital School of Medicine, London, England
  • Notes:
    DA - 19891024
Abstract
In vascular pathology the assessment of disease severity and monitoring of treatment requires quantitative and reproducible measurements of arterial blood flow. We have developed a new technique for processing sequences of dynamic digital X-ray angiographic images. We have tested it using computer simulated angiographic data which includes the effect of pulsatile blood flow and X-ray quantum noise. A parametric image was formed in which the image grey-level represents dye concentration as a function of time and distance along a vessel segment. Adjacent concentration--distance profiles in the parametric image were re-registered along the vessel axis until a match occurred. A match was defined as the point where the sum of squares of the differences in the two profiles was a minimum. The distance translated per frame interval is equal to the bolus velocity. We have tested several contrast medium injection methods including constant flow and a range of discrete pulses per second. The technique proved to be robust and independent of injection technique. Average blood flow was measured for simulated pulsatile waveforms with mean flows of up to 650 ml/min (peak velocities up to 186 cm/s) in a range of diameters from 2 mm to 6 mm. The standard deviation of the error in the mean flow estimates over the whole range of velocities and vessel sizes was +/- 1.4 cm/s