An in vivo and in vitro investigation of the use of ICDAS, DIAGNOdent pen and CarieScan PRO for the detection and assessment of occlusal caries in primary molar teeth
Abstract
Objectives The aim of this study was to investigate the in vivo and in vitro validity of International Caries Detection and Assessment System (ICDAS), DIAGNOdent pen and CarieScan PRO in the detection and assessment of occlusal caries in primary teeth. Methods Sixty-four molars were assessed using all three systems under standardised in vivo conditions. They were then extracted and assessed by two examiners in vitro along with an additional 38 teeth (102 teeth in total from 45 children). Downer’s histological scoring criterion was the validation gold standard. Sensitivity, specificity, positive and negative likelihood ratios and area under the receiver–operator curves were calculated for all caries and dentine caries. Repeatability was analysed using Cohen’s Kappa and the performance of the systems between in vivo and in vitro settings by the same examiner were compared. Results ICDAS showed the highest validity and repeatability. The DIAGNOdent pen’s overall clinical validity was comparable to that of ICDAS, but it demonstrated only moderate repeatability. CarieScan PRO had negligible validity in vivo, and there was no relationship between in vivo and in vitro parameters. Conclusions The in vivo results of ICDAS and DIAGNOdent pen were satisfactory and comparable to those obtained in vitro, with ICDAS performing better. The CarieScan PRO performed poorly under both conditions. Clinical relevance ICDAS should be the index of choice when detecting and assessing occlusal caries in the primary dentition, and in vitro data can be safely extrapolated in vivo. The DIAGNOdent pen must be employed with caution. Currently, the CarieScan PRO is unsuitable for use in the primary dentition.
Publication data is maintained in RPS. Visit https://rps.ucl.ac.uk
 More search options
UCL Authors
Craniofacial & Development Sciences
Continuing Professional Development
University College London - Gower Street - London - WC1E 6BT Tel:+44 (0)20 7679 2000

© UCL 1999–2011

Search by