Detailed analysis of data from heat pumps installed via the Renewable Heat Premium Payment Scheme
-
Publication Type:Report
-
Authors:Summerfield A, Biddulph P, Stone A, Grainger C, Agnolucci P, Gleeson C, Oikonomou E, Lowe R
-
Publisher:Department of Energy & Climate Change
-
publication date:2017
-
Status:Published
-
Language:English
Abstract
The RHPP policy provided subsidies for private householders, Registered social landlords and communities to install renewable heat measures in residential properties. Eligible measures included air and ground-source heat pumps, biomass boilers and solar thermal.
Around 18,000 heat pumps were installed via this scheme. DECC funded a detailed monitoring campaign, which covered 700 heat pumps (around 4% of the total). The aim of this monitoring campaign was to assess the efficiencies of the heat pumps and to estimate the carbon and bill savings and amount of renewable heat generated.
Data was collected from 31/10/2013 to 31/03/2015. This report represents the analysis of this data and represents the most complete and reliable data in-situ residential heat pump performance in the UK to date.